ABB_800xA学习笔记202:System_800xA_Control_6.0_AC_800M_Getting_Started_42附件A-7

(2023-12-03 12:07:22)
标签:

abb

system_800xa_ac800m

入门手册

附件a

分类: ABBDCS
继续学习入门手册附件A
Re-Authentication
重新身份认证
The Re-Authenticate function is used to ensure that a user is authorized to download a project. If the function is enabled, a dialog is shown and you will be asked to enter name and password before the download is carried out.
重新身份认证功能用于确认用户经过授权进行项目下载。如果启用该功能,显示对话框,在执行下载前要求你输入名字和密码。
ABB_800xA学习笔记202:System_800xA_Control_6.0_AC_800M_Getting_Started_42附件A-7
Figure 66. Re-authenticate dialog
图 66. 重新认证对话框

Disable/Enable Re-Authenticate function
取消/启用重新认证功能
1. Select Tools > Setup > Station > Application Download. A ‘Setup Application Download’ dialog opens.
选择工具 > 设置 >站 > 应用下载。 打开下载应用程序设置对话框
2. Set the parameter ReauthenticateDL to true/false. The function is enabled per Control Builder station.
设置参数“重新认证"为真/假。为每一个控制器启用功能。

Compiler Switches
编译器开关
Configurable switches in the compiler allow you to introduce extra restrictions on code. The restrictions are divided into:
可以对编译器中配置开关,允许你对代码引入额外的限制。限制分为:
  • Global restrictions 全局限制
  • SIL restrictions  SIL限制

Global restrictions are valid for all code. SIL restrictions are valid only for code marked SIL1-2 and SIL3. For SIL1-2 and SIL3 code, there are also mandatory restrictions, which cannot be changed.
全局限制对全体代码有效。SIL限制只是对标记为SIL1至2,和SIL3的代码有效。对SIL1至2和SIL3的代码,还有强制限制,无法更改。
A restriction can have the values:
限制可以有以下数值:
  • Allowed  允许
  • Warning  警告
  • Error  错误

Mandatory SIL1-2 and SIL3 restrictions are always errors.
强制SIL1至2和SIL3的限制始终是错误的。
The restrictions are checked during the check of each type, and also during the compilation. If you change a restriction, the project will be re-compiled when you perform a download of the project, and the code will be validated with the new restriction.
在检查每种类型以及编译期间都会检查限制。如果修改限制,当你执行下载项目时,项目将重编译,代码将使用心得限制进行验证。
Restrictions makes it possible to warn against or forbid things that may result in complex code and thereby errors. For example, to check the usage of Instruction List language, you can change the corresponding switch from “Allowed” to “Warning”, and you will get a compilation warning if there is any IL code in the project. Another example is when a new library is imported, you can then turn all switches from “Warning” to “Error” to check the the quality of the new library..
通过限制可以警告或者禁止可能导致复杂代码并因此发生错误的事情。比如,要检查指令表语言使用情况,可以将相应的开关从允许变为警告,如果项目中有任何IL代码,你将受到编译警告。另外一个例子是当导入新的库,你可以将所有的开关从警告变成错误以检查新库的质量

Compiler switches are configured in the Compiler Switches dialog, which is displayed if you; right-click the Project Icon (e.g. MyDoors in Figure 13) and select Settings > Compiler Switches from the context menu. A ‘Compiler switches’window will open.
如果你鼠标右键点击项目图标(比如图13的MyDoors),从关联菜单选择设置>编译开关,在编译开关对话框配置编译开关
ABB_800xA学习笔记202:System_800xA_Control_6.0_AC_800M_Getting_Started_42附件A-7
Figure 67. Compiler switches dialog
图 67. 编译开关对话框

It is possible to exclude a library from a certain restriction, provided that the restriction is a warning. If a library is excluded, no checks are performed on the restriction for any type in that library. For example, if a new external library results in many warnings, you may want to filter out acceptable warnings to make it easier to read other warnings. Click Options in Compiler Switches dialog, and in the expanded dialog select the library to exclude from the selected restriction.
可以将某个库从某个限制排除在外,前提是该限制是警告。如果该库被排除,将不对该库所有的类型执行限制检查。比如。新的外部库导致许多警告,你可能像过滤出可接受的警告,以便更加简单的阅读器他警告。点击编译开关对话框的选项,在展开的对话框从选择的限制中选择排除的库。
ABB_800xA学习笔记202:System_800xA_Control_6.0_AC_800M_Getting_Started_42附件A-7
Figure 68. Compiler switches, excluding library from restriction.
图 68. 编译开关,从限制排除库