ABB800XA学习笔记127:systemtools

(2023-11-07 20:22:24)
标签:

abb

800xa

systemtools

分类: ABBDCS
继续学习。
Set Default Drive
设置默认驱动器
When adding a server you might not want to have the Workplace Data of the system on the same drive as the Installation Files. You can change this by selecting Set Default Driver for remote actions, and select your own drive. See Figure 34
添加服务器时,您可能不希望将系统的工作区数据与安装文件放在同一驱动器上。您可以通过选择“为远程操作设置默认驱动程序”来更改此设置,然后选择自己的驱动器。参见图 34。
You must change the drive locally in the server before you can add it to the system.
您必须先在服务器中本地更改驱动器,然后才能将其添加到系统。

ABB800XA学习笔记127:systemtoolslaiguzhanggenzhong
图 34

Change Service Account Password
修改服务账户密码
If the password for the windows account used as the 800xA Service Account is changed it is also necessary to update the stored logon password on each node in the system. This can be done with System Software User Settings if the system on the node can be shutdown.
如果更改了用作 800xA 服务帐户的 Windows 帐户的密码,则还需要更新系统中每个节点上存储的登录密码。如果节点上的系统可以关闭,则可以使用系统软件用户设置来完成此操作。

If it is desired to change the password “on the fly”, Change stored logon password for the service account must be used. In this way the new password will be used on the next service logon. The stored password will be updated for the ABB Service
如果需要“即时”更改密码,则必须使用更改服务帐户的存储登录密码。这样,新密码将在下次服务登录时使用。存储的密码将针对ABB服务进行更新。

Manager and ABB 800xA Notification Service. Stored passwords will also be updated for the AppLog service and Client Service Provider service if they use the same account as the 800xA Service account
管理和ABB 800XA通知服务。如果AppLog服务和客户端服务提供商服务使用与800xA服务帐户相同的帐户,则存储的密码也将更新。
1. Mark the Change Service Account Password radio button. See Figure 35
标记更改服务帐户密码单选按钮。参见图 35
ABB800XA学习笔记127:systemtools
图 35
2. The service account name is shown by default
默认情况下显示服务账号的名字
3. Enter the new password (the password set in the domain) in the Password text field. Click Next.
在密码文本中输入新密码(在域中设置的密码)田。单击“下一步”。
4. Click Finish in the next dialog box
在下面的对话框点击完成按钮

AppLog
AppLog is a tool for getting information of an IndustrialIT 800xA System and for examining how the system is working.
AppLog 是一种用于获取工业IT 800xA系统信息并检查系统如何工作的工具。
The Applog tool is mainly used by ABB service engineers
Applog工具主要由ABB服务工程师使用

Start AppLog
启动Applog
To configure the AppLog manually follow the steps below:
要手动配置AppLog,请按照以下步骤操作:
1. Select Applog in the Configuration Wizard and click Next
在配置向导选择Applog,点击下一步
2. Mark the Enable AppLog Service check box in the Applog configuration dialog box. Enter the User ID with domain and password in the AppLog service settings area.
在Applog配置对话框中勾选启用AppLog服务复选框。在AppLog服务设置区域中输入带有域和密码的用户ID。
Mark the Autostart service on Windows startup check box. AppLog will then be started when Windows is started. Select Start in the Action area.
选中“Windows 启动时自动启动服务”复选框。然后,当 Windows 启动时,AppLog 将启动。在“操作”区域中选择“启动”。
ABB800XA学习笔记127:systemtools
图 36
3. Click Next.
点击下一步
4. Click Finish in the Apply Settings dialog box
在应用设置对话框点击完成按钮

Stop AppLog
停止Applog
To stop the AppLog server follow the step below:
按下列步骤停止Applog
1. Select Applog in the Configuration Wizard and click Next.
在配置向导对话框选择Applog,点击下一步
2. Select Stop in the Actions area
在动作区域选择停止
3. Click Next then click Finish. The AppLog server is now stopped
点击下一步,然后点击完成。Applog服务现在停止。

Restart AppLog
重启Applog
To restart the AppLog server follow the steps below:
按照下列步骤重启Applog
1. Select Applog in the Configuration Wizard and click Next
在配置向导选择Applog,点击下一步
2. Select Restart in the Actions area
在动作区域选择重启
3. Click Next then click Finish. The AppLog server is now restarted
点击下一步,然后点击完成。Applog服务现在重启了。

Disconnect Client
断开客户端
This task is only available on a client node when the client is connected to a system. To disconnect a client follow the steps below:
此任务仅在客户端连接到系统时在客户端节点上可用。断开客户端连接的步骤如下
1. Select Disconnect Client in the Configuration Wizard, click Next
在配置向导选择断开客户端,点击下一步
2. Choose the system from which the client shall be disconnected, click Next
选择客户端要断开的系统,点击下一步
3. Click Finish. The client is now disconnected from the system and the Configuration Wizard window will appear
点击完成按钮。客户端从系统断开,将出现配置向导窗口。
In the Diagnostics task you can configure the Watchdog function
在诊断任务你可以配置看门狗功能
The Diagnostics settings should only be used by ABB service engineers
只有ABB服务工程师可以使用诊断设置

To configure this function follow the steps below:
按照下面的不愁配置此功能
1. Start the Configuration Wizard and select Diagnostics and click Next
启动配置向导,选择诊断,点击下一步
2. To enable the Watchdog function select the Enable Watchdog check box, see Figure 37. When this function is enabled, unresponsive windows are indicated with a red frame. The Heartbeat Time is by default set to 30 seconds. A dump file can be saved containing information about the state of the Diagnostics workplace. This information can be used by ABB service engineers to facilitate
their fault tracing.
若要启用看门狗功能,选中“enable Watchdog”复选框,如图37所示。当启用此功能时,无响应的窗口将用红色框表示。心跳时间默认是30秒。存储文件包含诊断工作区的状态信息。ABB服务工程师可以使用此信息来故障跟踪。
ABB800XA学习笔记127:systemtools
图 37

3. Click Next when you are done with the configuration.
当完成配置后点击下一步
4. Click Finish in the Apply Settings dialog box.
在应用设置对话框点击应用按钮

第二章的学习到此结束