Package Thermal Resistance Values (Theta JA, Theta JC) f

Package Thermal Resistance Values (Theta JA, Theta JC) for Temperature Sensors and 1-Wire Devices From:http://china.maximintegrated.com/app-notes/index.mvp/id/3930 |
Abstract: Two common thermal-resistance values
measured for IC packages are junction to ambient (Theta JA) and
junction to case (Theta JC). These parameters are useful for
calculating maximum power dissipation and self-heating, and for
comparing package types. Theta JA and Theta JC values are presented
here for select Maxim temperature sensors and 1-Wire® devices.
Examples for calculating the values are
given.
Introduction
Managing heat in electronic systems is crucial for
ensuring product reliability. Integrated circuits (ICs) exposed to
high temperatures can fail or malfunction in the field, thus
requiring costly repair or redesign. Typical thermal-resistance
parameters give the
This application note lists Theta JA and Theta JC
values for select Maxim
Theta JA and Theta JC Values
Tables 1
http://s13/mw690/628dd2bctd82c5cccf7dc&690Thermal
http://s1/mw690/628dd2bctd82c5cdc5690&690Thermal
Precautions for Using Theta Values
Using the values in Tables 1 and 2 for any conditions that differ from the JEDEC standard will nearly always result in calculation errors. In fact, the JEDEC standard 51-3 specifically states, "It should be emphasized that values measured with these test boards cannot be used to directly predict any particular system application performance but are for the purposes of comparison between packages."¹
The values do not account for irregular board sizes, enclosed packages, heating from nearby ICs, all factors which can all affect application-specific temperature changes. When using application-specific boards, actual temperature measurements and further analysis are needed.²
Self-Heating Calculations
Occasionally the power dissipation of a temperature sensor
causes the device to measure a temperature greater than ambient.
This phenomenon is known as self-heating. By using Equation 1, the
Theta JA value can be used to estimate the
IC's
http://china.maximintegrated.com/images/appnotes/3930/3930Eq01.gifThermal |
(Eq. 1) |
The
http://china.maximintegrated.com/images/appnotes/3930/3930Eq02.gifThermal
For the worst-case scenario, the DS1620 junction temperature rises less than 1/4°C, so self-heating is only a minor concern for this particular packaged device.
Maximum Power Dissipation
The theta values can also be used to approximate the
maximum power dissipation allowed for a specific packaged device.
This calculation can help determine whether the package alone
dissipates enough heat, or if an external
Assume, for example, that your application has a
maximum
http://china.maximintegrated.com/images/appnotes/3930/3930Eq04.gifThermal |
(Eq. 4) |
To safely use the DS1620 in an SO package, therefore, the maximum power must be limited to 541mW. Power consumption greater than that would require reducing the ambient temperature or adding a heat sink to dissipate more heat. The maximum power consumed by the DS1620 was already shown to be 8.7mW, so this application is safe in the SO package.
Comparing Package Types
Theta values are defined so a designer can compare different package types for a specific application. This analysis requires that the actual junction temperature be measured in the specific application. This measurement can be done for a temperature sensor by simply reading the temperature from the part. An accurate reading of the ambient temperature must then be known. With these two temperature measurements, the actual delta above ambient is known. This information and the Theta JA values can be used to compare two package types. By using Equation 5, the temperature rise of a different part can be estimated.³
Assume, for example, that the DS1620 had a temperature rise
of +0.241°C in an application. Then the designer wanted to estimate
the temperature rise of another smaller device like
the
As shown in Equation 6, the temperature rise in the DS1626's smaller package is significantly more than for the DS1620. Yet, the temperature rise is proportional to the ratio of Theta JA values. This comparative method of analyzing temperature and power dissipation between devices is why the theta values were created. The resulting calculations are reliable.³
Summary
The package thermal-resistance values, Theta JA and Theta JC, can be useful in determining the thermal response of ICs in a JEDEC-constrained environment. Under any other conditions, the calculations are likely to deviate from measured parameters. While the theta values can be useful in approximating self-heating characteristics and maximum power dissipation, their primary purpose is to compare the thermal performance of one package to another.
References
1.
2.
3.