PCR实验室基本要求
(2022-07-07 11:00:37)2.1 PCR
实验室依据所使用的方法可分为试剂准备、标本制备、扩增、产物分析等三或四个区域。只是使用实时荧光PCR仪、HIV病毒载量测定仪的PCR实验室,有上述前面三个区域即可。各区域应完全独立分隔,不应有任何的空气直通。Based
on the methods used by PCR lab, the PCR laboratory can be divided
into three or four rooms or areas for (i) reagent preparation, (ii)
sample preparation, (iii) amplification area, and (iv) product
analysis area. If the PCR laboratory only uses real-time
fluorescence PCR instruments and /or instruments for HIV virus
load, the PCR lab may have only the first three rooms or areas
(reagent preparation, sample preparation, amplification). The rooms
or areas of the PCR lab should be independently separated, and
there is no air flow through the separated rooms or areas.
2.2产物分析区或三个区域的最后一个区域(即扩增及产物分析区),空气流向应由室外向室内,可通过在室内设置通风橱、排风扇或其他排风系统达到空气流由室外向室内流动的要求。
For PCR product analysis area or last area of three areas
(area for amplification and product analysis), direction of air
flow shall be from outside to inside of the area by setting up fume
hood, exhaust fan or other exhaust system in the area.
2.3 PCR实验室各区域仪器设备配备通常如下:The equipment configuration for PCR
labs are as follows:
2.3.1试剂准备区: Reagent preparation area
仪器设备主要应有加样器、冰箱、天平、低速离心机、混匀器、可移动紫外灯等。可使用超净工作台作为试剂配制操作台面。
The main equipment here should be: pipette, refrigerator,
balance, low speed centrifuge, vortex mixer, mobile UV lamp, etc.
It can use Laminar flow cabinet for the reagent preparation.
2.3.2标本制备区sample preparation area
仪器设备主要应有生物安全柜(最好为B2,
可避免提取核酸在柜内反复循环,造成标本间交叉“污染”,出现假阳性结果。此外还应配备加样器、台式高速离心机(冷冻及常温)、台式低速离心机、恒温设备(水浴和/或干浴仪)、冰箱、混匀器和可移动紫外灯等。
The main equipment is the bio-safety cabinet (type B2 is
better, because it can avoid recycling of nucleic acid cabinet and
cross contamination of specimens). Besides, it shall be equipped
with pipettes, centrifuge table high speed (refrigerated and normal
temperature), centrifuge table low speed, constant temperature
devices (water bath or dry bath), refrigerator, vortex mixer and
mobile lamp UV etc.
2.3.3扩增区amplification area
前一篇:PCR实验室安全准则
后一篇:PCR实验室要求规划